46. Render - Web
To test in: Web
Purpose of the test is to make sure rendering is smooth and changes are applied consistently to all visualisations of the images and all the options of rendering are functional.
Note: For all copy and paste tests, the copied settings must be pasted to a Dataset of Images/Image or Plate/Well that has the same pixel type and number of channels as the image the settings were copied from. It is suggested that changes made to settings for test purposes are obvious and easily recognisable.
46.1. Render - basic
Use right-click to copy settings from an image.
Check that the right-click menu comes up only when selecting in the left-hand pane tree, not in central pane [RenderWeb003:].
Select a collection of images and use right-click to Paste and Save the settings.
Check that the thumbnails in the centre pane and the Preview viewer and User Settings thumbnail update.
Select a well in a plate and change the settings then use right-click to
Copy
and thenPaste and Save
the settings to the whole plate using right-click.Check that the images in the wells in the centre pane and the Preview viewer and User Settings thumbnail update.
In Preview [RenderWeb004], change the settings using
Sliders.
Color picker [RenderWeb004b].
Toggling a channel on and off.
Copy settings which were not saved, do NOT paste, then
Navigate to another image, copy settings from it (settings which were saved, e.g. using right-click on the image in the tree) then
Paste in Preview of a third image and Check that the second (most recently copied) settings were pasted.
Open the Full Viewer from the Preview tab using
Launch Full Viewer
button.Check that the Full Viewer shows the same Rendering settings as the Preview.
Check that the size of the image in the Full Viewer is such that it fits into the window, not smaller.
Paste something into the Full Viewer and Check that the Full Viewer updates.
Change the Rendering settings in the Full Viewer and press Save. Check that Preview viewer and User Settings thumbnail updates.
Copy the unsaved Rendering settings from the Preview pane of an image and Paste them
in the Full Viewer of another image.
in tree, using right-click menu [RenderWeb003:].
in Preview pane of another image.
do all 3 Paste actions also on Plate (in tree) and on single Wells in Plate (Full Viewer & Preview). Note that the
Save to All
button is disabled for Plates when single wells are selected.Check that the Rendering settings were updated after Paste in all cases.
In context (right-click) menu, execute the
Set Imported and Save
on a Plate Run and Check that this does revert the Rendering settings to its original state at import.Min Max.
Import a few images. Go to Preview.
Check that for each channel the start-end is set to the min-max.
Select images imported previously (not the newly imported ones).
Click
Imported
button.Check that for each channel start-end = min-max.
Repeat steps 1. - 6. working on orphaned images.
Repeat the steps 1. - 6. with Big Images (Find suitable images here [
TestingSet
] or here [TestingTemplate
]).
46.2. Render - copying / resetting
Copy settings in the Full Viewer [RenderWeb002:] ) and paste them.
in the Full Viewer of another image.
in tree, using right-click menu [RenderWeb003:].
in Preview pane of another image.
do all 3 Paste actions also on Plate (in tree) and on single Wells in Plate (Full Viewer & Preview).
Check that the Rendering settings were updated after Paste in all cases.
Reset imported settings - use the
Set Imported and Save
button in the right-clcik context menu, Full Viewer (click onEdit
link first) and Preview.Check that thumbnail(s) in the central pane is (are) updated.
Check that when you select Plate Run and in context menu select
Set Imported and Save
, no error occurs.
Set min/max settings in Preview and Full Viewer. Press
Save
in both cases andCheck that thumbnails in the central pane are updated.
Set owner’s settings [RenderWeb005] in right-click menu. Perform also on whole Dataset.
Check that thumbnails in the central pane are updated.
Make sure you have images in “Orphaned Images” folder (get them via CLI import or do Cut command).
46.3. Other users’ data
Other users’ data - basic.
Open an image belonging to another user.
Modify the settings in the “Preview” pane or click
Edit
in the Full Viewer to modify settings. Save your own setting using theSave
button [Render007:].Check that thumbnails in the central pane are updated.
Use
Save to all
button.Check that all thumbnails in a Dataset or all wells in a Plate Run are updated.
Other users’ data - Owner’s settings.
Import at least 2 multi-t and multi-z images as a user (e.g. user-4) in Read-Only group.
Go to the imported images and modify the Rendering settings in such a way that you can recognize these settings easily later.
Log out and Log in as an Owner of Read-Only group (e.g. user-3).
View the images you just imported as another user (e.g. user-3 viewing user-4’s images).
Check that, still as a default you can see the Rendering settings you just saved as the owner of the image (for example user-4).
Check that when you change Rendering settings and click
Save
in Preview pane, your own settings appear in the list underUser Settings
.Change Rendering settings and click
Save to All
in Preview pane, followed by clickingImported
in Preview pane and againSave to All
.Check that the thumbnail in the centre pane, the viewer in Preview, the thumbnail in User Settings and the image in the Full Viewer still match.
Check that under
Preview > User Settings
the settings of the owner are hightlighted blue.
Repeat step 2, this time in Read-Annotate and Read-Write groups (note that you do not have to be Owner in these groups to save your own settings on other’s images).
Import images as a user (e.g. user-4) in Read-Only group and modify Rendering settings in easily recognizable manner. Log out, Log in to Web as an Administrator (e.g. user-6), which is NOT an Owner of Read-Only group and view the images you just imported.
Check that you can see the Rendering settings you just saved as the owner of the image as a default.
Check that when you can change the settings (still in Web) and Save the new settings, the thumbnail, the Preview and the Full Viewer match and they have the newly created and saved settings.
Click
Set Imported and Save
in Web and go to Insight, logging in as the owner of the image - Check that you have your settings as well as the Admins settings (= the Rendering settings of the image owner have not been deleted or overwritten by the actions of the Admin in Web.Check that under
Preview > User Settings